Direct wire LED tube lights were traditionally wired at just one end and required the use of non-shunted tombstones only, but we now carry double-ended … Order now for only $14.99 each! Use the compatible LED tube light is a stopgap at present, which is designed for help people who not as professional as you to save some time and money to hire someone to do the rewire job for them. Designed for Max Lumens Output. The electrical rating of this product is 120-277V, before installing confirm the fixture has 120-277V. I’m looking to install a bunch of garage lighting. One of 20 kinds of electronic ballast is a problem? 8 Foot 4 T8 LED Strip Fixture. 2 Philips Advance Ballast Quick Guide 3 Introduction 4 T8 ballasts 6 T5 ballasts 7 CFL ballasts 8 Magnetic T12 conversion to electronic 9 T12 … 1,088 t8 fixture ballast products are offered for sale by suppliers on Alibaba.com, of which ballasts accounts for 5%. Have a question? The T8 models cost almost half of the T12. You may not be able to see it easily visually, but if you are under it for long periods of time, it may be headache inducing or at least eye fatiguing. However, I had a constant hot attached to the previous wiring so the light would remain on 24/7. Review. These DesignLights Consortium (DLC) qualified LED T8 lamps are designed to provide appropriate light levels while utilizing a dedicated internal driver. PROLIGHTING recommends installing LED-ready T8s in warehouses, gymnasiums, machine shops or any other large space with a high ceiling, as these lights will provide broad-spanning light across a large environment. No items selected. 20 Pack 4FT LED T8 Ballast Bypass Type B Light Tube, 18W, 2400lm for Single-Ended & Dual-Ended C… most efficient light available – and will make you wish you had replaced your lights sooner! Bartco Lighting BFL250 17W T8 Fluorescent Low Profile Strip Fixture, No Ballast. What’s the problem? 4 thoughts on “ Retrofit t12 to t8 … The 45-watt T8 bulb is capable of replacing a 100-watt traditional bulb with the help of its top quality LED chips. IH2-UNV-270-T8 UPC 872180106366 No. T8 & T12 Type B Ballast Bypass Fluorescent Replacement; Converts your existing fluorescent fixture to LED technology using 4-foot universal bulb replacements for both T8 and T12 lamps; No need for a ballast - install with simple wiring of the fixture to bypass the ballast; Cool White vibrant light ideal for work spaces and task lighting Whatever your business entails, from factories, manufacturing facilities, warehouses and machine shops to to greenhouses and gymnasiums, lighting is important, 15W LED T8 4FT 5000K BALLAST COMPATIBLE Item No: LT15T84850. With Vi-Tek 93 ® Plus LEDs it's truly like taking the roof off the building to let the daylight in. and our multi-faceted, exclusive reflectors ensure their light shines brightly and evenly, with no shadows or hot spots. Locate The Ballast On The fluorescent Light Fixture. The lumens are generally lower, too. http://i1166.photobucket.com/albums/q609/dchomak/A6A6DAD2-B6D6-484F-A1E3... http://i1166.photobucket.com/albums/q609/dchomak/3181d22d-4a19-4f5c-bb88... http://imgur.com/xudHRS3][img]http://i.imgur.com/xudHRS3.jpg[/img][/url], http://imgur.com/T1vDJ52][img]http://i.imgur.com/T1vDJ52.jpg[/img][/url], http://imgur.com/D0JQTtd][img]http://i.imgur.com/D0JQTtd.jpg[/img][/url]. Also the tombstone bits are shunted, which means they need replaced before using with LED direct wire tubes. If you want the ‘fixture’ without the ballast, the easiest way is probably to just buy some of the sockets, and screw them to a 2” × 4” or something, run some wire, and away you go. NEVER have I seen the price for 2 replacement bulbs cheaper than an LED fixture with bulbs. This universal lamp can be installed in fixtures with or without a ballast, making it ideal for applications where the fluorescent systems are being upgraded to save energy and maintenance costs. T8 LED LINE VOLTAGE No external ballast or driver required; operates on universal 120-277V line voltage • Single-end powered, solid state replacements for linear fluorescent tubes • Suitable for use in totally enclosed fixtures • Existing fixture maintains original UL compliance per UL1598C listing • 9W–43W; 2’/3’/4’ length T8 LED DUAL MODE Hybrid Dual Mode for use with programmed/instant start ballasts … Also the satisfaction of doing it yourself. installed in the fixture — No warm-up time, instant-on with full light output and stable lamp to lamp color — No UV emission — Approved for use with tube guards — Maximize energy savings with occupancy sensors — Up to 120 LPW (Lamp efficacy) — CCT: 3500K, 4100K, 5000K — CRI: 80 — Light Emitting Angle 340°; Beam Angle 220° Electrical — Installed directly on 120-277V; no ballast required — Power factor … Existing fixture is wired to bypass the ballast; Reduces energy use (vs type A) Eliminates the need to check ballast compatibility. Anyway these reflector/fixtures have power cords attached but they can be reworked for permanent wiring if you want to do that. T8 Fluorescent & Compact Fluorescent (CFL) Ballasts 164 products Fluorescent ballasts and compact fluorescent (CFL) ballasts install into compatible lighting fixtures to protect fluorescent and CFL light bulbs from damaging power fluctuations that can reduce the quality of the bulbs' light output. The cold rolled steel body is painted with a smooth, glossy, highly reflective white enamel paint and has sufficent knockouts for mounting and electrical supply. Hi, You have three choice for this LED lighting transformation. Now, locate the ballast on the existing fluorescent fixture. Evenly Spreads Light. Add A Power Cord. I had a flourescent fixture in the kitchen of all places - 4 tubes - and swapping those out made a huge difference. Most T8 tubes will have a hidden ballast, covered with a casing and resting behind the tube light. I know you can buy whole assembled for around that price, but I want to choose my tubes and not get the crappy ones that come in those all-in one solutions. Purchasing Options: Fixture Qty. I've bought these T8 fixtures from Home Depot at $14.99 each. Ballast factor efficiency refers to the actual lumen output for a specific lamp and ballast system as compared to its rated lumen output. [Back to Top]     [Home]     [Privacy Policy]. $24.99. Product Description. Adding to your cart. I've found a source at 69 cents each and I only need to replace two of the four for each housing. We have the list of the electronic ballasts, which are compatible and which are not. Add A Power Cord. https://qph.ec.quoracdn.net/main-qimg-99c371388e64564275cb17958bee6cc1-c... Use the lamp holder with input power wire directly, install them on the wall with a length fit for the 4ft LED T8 tubes. LED T8, Ballast By Pass —Installation Guide WARNIG: Before installing make certain the power is off. The Active Grow T8 HO Horticultural Fixture comes prewired and ready for use with Active Grow T8 HO Ballast Bypass Universal Voltage (120-277V) Lamps. Kill power, remove 48" or 96" T12's, snap out trough cover, undo 2 ballast nuts and change wires, jumping out starters if fixture had them. Our Vi-Tek 93® Plus LED sticks are the best natural daylight, full-spectrum fluorescents lamps on the market – 7 Year Warranty. 1800 Lumens - 4 ft. Evenly Spreads Light. I have had my eye on T-8 LED replacement bulbs for quite awhile now. The old glass fluorescent tubes need that electrically grounded metal shell close to them to light up properly, at least in cold weather When I removed cover and looked for ballast, there was none and when I looked above the dropped ceiling, the flex conduit ran straight to another light in the room. Plug-and-play T8 lamps operate with the fixture's existing fluorescent ballast, so no rewiring is necessary. "Gatling Rotary Fixture" 4-tube (In Development) T8 LED tube light fixture 6500K 2x18 LED tri-proof tube light fixture 1200mm LED tube light fixture replace florescent bulb US $4.00-$9.00 / Piece 100 Pieces (Min Order) Assuming the fluorescent lights you're replacing are run by an electronic ballast (rather than an old magnetic ballast), it's a light bulb swap like any other. T8 LED Wiring Instruction Diagram for Multiple Tubes Vi-Tek 93® Plus LED sticks with this exclusive fixture provides the highest quality, No items selected. Same color temperature but not as bright and $30 / 3700 lumens / fixture. I wonder why HD has put them on fire sale so soon. Use the ballast bypass 43 watt linear LED anywhere an 8 foot T8 and T12 fluorescent bulb is used. If you really prefer not to do that, then you'll need to just try it out. So far these are the most appealing LED T8’s: https://www.earthled.com/collections/led-t8-tube-replacements-replace-yo... Ballast bypass, 4000k, 2000 lumens each, 8.99 each when I buy in bulk. Sign in to check out Check out as guest . Hey, Hank. I have about 2 ballast T12 lights. It's better to just get rid of the ballast. Review. 2. If you really do not know it, you need keep learning, check the following chart from GE Lighting – LED tube light replacement instruction. The first thing you need to know is that there are three kinds of fluorescent fixtures: magnetic (inductive) ballast, electronic ballast, and instant-start ballast. The drivers are enclosed inside the end cap, offering … A wide variety of t8 fixture ballast options are available to you, such as lighting and circuitry design, project installation. The metal fixture will protect your electrical contacts and if you get a short, or worse a weak connection that heats up, or a bad tube, or …. Premature ballast failure is often caused by the surrounding environment. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more. (a decade or two ago I thought I understood why that was, something about the charge inside the tube behaving better) I bought four of those LED Shop Lights from Costco. 2) Cold (neutral, white) wire to any of other three pins on troffer. No ballast change. In my garage (picture posted earlier) I want the lights butting up against each other. Sold only by the Case of 25 for $98.82 More Info. Many replacement ballasts can be wired for several combinations of lamps, such that a 4-lamp ballast can be wired to a 3 or 2 lamp fixture. The reflectors are attached to the fixture body with a tab lock system. The Active Grow T8 HO Horticultural Fixture comes prewired and ready for use with Active Grow T8 HO Ballast Bypass Universal Voltage (120-277V) Lamps. btw, if you are retrofitting, simply ignore the ballast, i snipped all wires to and from and proceed to wire the bulbs. Well, one advantage of modding is that you can get exactly what you want. Fax: 309-742-7071. These LED T8 lamps contain no mercury, provide instant light and a uniform light distribution. A-Plus Lighting has 10 years experience of LED high bay light and downlights producing, working with us - your customer will thank you and always remember! Simplest Total System, Direct Wiring to Mains. My house was built in the 70's and no "starters" on any of the fluorescent fixtures. Instant Start, Flicker Free. I probably should have got the next step down in light output. Make sure what you buy is UL certified - it should at least be safe in that case. – Up to 6% in energy savings compared to standard efficiency T8 electronic ballasts without compromising light output – 50% energy savings when compared to typical magnetically ballasts 400 metal halide systems 2. Searching for T8 Emergency Ballasts for Fluorescent or LED Retrofit Light Bulbs? That’s an interesting idea. Emergency ballasts install into lighting fixtures that contain fluorescent linear light bulbs or UL Type C LED retrofit linear light bulbs that are powered by fluorescent ballasts. The fixture is just bent sheet metal, but it hides the wires away and holds those socket things nicely. Cord and Plug Add $13.99 per fixture Oversized Box: Call for shipping quote. No tools or additional fasteners are required for reflector installation and removal. Features. SKU 24275 Brand Fulham Manufacturer Part No. LED T8 … Are there any manufacturers selling fixtures like that? So I did 9 fixtures for $131.00 at 4800 lumens per fix. There are also these fixtures from Costco: http://www.costco.com/4%25E2%2580%2599-Linkable-LED-Shop-Light-with-Pull-Chain-2-pack.product.100284402.html In other words, the ballast works directly with a driver that is inside the LED, making installation is easy. I wired mine direct from incoming power leads to tombstone connectors. I also get that if you have an existing fixture that incorporates these it might be easier to exchange the can rather than rebuild the fixture but fortunately I haven't found myself in that situation. Color characteristics in T8s have improved dramatically so that the standard T12 with its larger tubes has become obsolete. HD has PLENTY of the 14.99 fixtures :). LED T8 Tube - Ballast Bypass - 15 Watt - 4000 Kelvin Single-Ended Power - 120-277 Volt - Case of 25 - PLT-90031 $3.95 ea. This is an important part of understanding the fixtures of T8 LED tube lights. But now that you're started I imagine you'll want the same look all the way through. Universal Voltage 120-277 Volt. My dream is that someone sells a non-shunted, ballast-less 4’ T8 fixture (basically just the sheet metal and tombstone holders) for $10 – $15. Direct AC (Ballast Not Required) 30 Watts. Replace your fluorescent tubes and remove the ballast with this energy-efficient long-lasting T8 LED tube to see substantial energy savings over the tube's lifetime. Ballast-bypass T8 LED tube pros and cons (UL type B) Ballast-bypass LED tube (Type B) pros: No ballast maintenance Removing the ballast simplifies the number of fixture components that need to be maintained. the install was easy, the light output was exellent. I might try to sell them. Spec Sheet: How to … Wiring Fluorescent Lighting Fixtures Electrical Question: How do I convert my T12 light fixtures to the T8 electronic ballasts? 3) Insert T8 LED Replacement into luminaire Fixtures with NO Ballast . I am trying to help a friend in an office building (used to be a bank, but remodeled) replace a bad ballast for a fluorescent fixture that holds 3 t8 4 foot bulbs. Active Grow T8 HO LED grow lights feature lower power consumption, 30% higher photon output and 100% more effective spectrums for plant growth vs. traditional fluorescent lamps. We’re here to help! In the end everyone will make their own decision but for me using "ballast compatible" is just a stopgap. M.T.C Canada Premium Range (120LM/WATT) LED T8 8 Feet Tube Light 36W 4320lm 6000K(Bright White) Frosted Cover CETL Certified Conforms To UL Std.1993 Certified To CSA Std.C22.2 No. With this tube, you can elect to utilize the existing ballast with no rewiring, or install directly without ballast. No ballast or starter necessary. $39.99 $ 39. Here’s the work in progress. H&H’s 8-foot 4 lamp T8 high-efficiency Watt-Hawk™ strip fixture is engineered to provide the highest output of light available. The type of existing lamps, the following are some examples. The electrician installed the new ballast and capped off the constant hot and just made the light work with the switch that controls the other lights in the room. These DesignLights Consortium (DLC) qualified LED T8 lamps are designed to provide appropriate light levels while utilizing a dedicated internal driver. While your point about buying stuff from retail channels is totally true people EasyLightForum would not be a very exciting website to visit. Shop ballasts and a variety of lighting & ceiling fans products online at Lowes.com. Here they are at $30.03. Shunted sockets must be replaced with a non-shunted type for the ballast bypass single end live power LED retrofit lamp to operate properly. Since it has no filament to break or burn out, you'll save even more on bulb costs with a tube that lasts twice as long as its fluorescent counterparts. If T8 and T12 are using the same bi-pin base (G13 most commonly), then you can use the bulbs interchangeably using the same fixture just as long as you check the milliamp requirements for the ballast (if applicable). The direct wire LED tubes run off of the line voltage that flows straight to the sockets. The item you've selected was not added to your cart. If there is no continuity across the contacts, the tombstone sockets are non-shunted and can be used with the LED tubes. Without the need for ballasts the fixture features lower heat, no buzzing … Is there any place I can buy a fixture built for T8 LED tubes that comes without a ballast? 55 products. With this option the fixture's ballast must be bypassed and removed. FREE Shipping by Amazon. 4,200 Lumens. I like these Luceco tubes. My panel lights are 7200 lumens vs the Lithonia panels are 4000 lumens (I think). When the LED lamp does need replacing, if you mistakenly try to replace it with a fluorescent, the lamp may not work or could be hazardous.In California, there are Title 24 requirements that need … If it is in the compatible range, you just use the LED tube replace your fluorescent lamp. Watch. 1993 No Need Ballast (Ballast Bypass) Direct line Voltage 100V-277V Extra Bright LED Bulbs Replacement for Fluorescent Fixtures Pack Of 20 Pcs Canadian Company Canadian Stock (FA8 MODEL (Single Pin)) No fires! Please forget that we need more time or cost to remove starter and ballasts, please stop worry about we will break the law because of a circuit rewire action. I can convert them in about 5 minutes each and be ready to go. Base Type: G13 - Medium Bi-Pin. I have a worklight that I built to suit myself and I absolutely treasure it. When it’s too hot or too cold, the ballast … If you want cheap Flouresent fixtures hit up craigslist. Due to the outlet on one side they don’t line up end to end very well. T8 LED Wiring Instruction Diagram (with NO Ballast) 1) Hot (black) wire (120V live wire) to any pin on one end of troffer. Also known as "ballast compatible" or "plug and play," these are LED tubes you can literally pop into your existing fixture and you're good to go. Wattage: 18 Watt (21W w/ ballast) Voltage: 100-277v. So for around $ 40 for the 2 tubes and the fixture, I'm good to go. WTH is an LED starter? Philips Advance 120 volt 2 lights Fluorescent Ballast For T8 See more like this. Well I don't know what THEIR answer is, but most issues I've seen with LED replacements is that they are so efficient that they do not provide enough load for the driver circuit to operate properly. Works with LED T8 Lamp Ready Fixtures Sunco Lighting 2 Pack Industrial LED Shop Light, 4 FT, Linkable Integrated T8 Fixture, 40W=260W, 60… "Gatling Rotary Fixture" 3-tube (In Development) 220-Watt T8 36-in. Fail to work? In many t8 fixtures the ballast is covered by a casing and the t8 tubes are on top of it meaning you need to take out the tubes and unscrew the casing to get to the ballast. They don’t look pretty and are a DIY job to mount but they work and you can’t beat the price. PROLIGHTING provides LED T8 fixtures in a … The type of existing lamps, the following are some examples. Our ballast compatible T5 and T8 lamps are the ideal energy saving, plug and play upgrade for your fluorescent fixtures. 25W-18 '' UV-C Germacidal Light-Fixture+ T8-NO OZONE+Standard ballast NOT-FAKE UVC `` Gatling Rotary ''! Hd but I was wrong body and prevent the lamps from slipping out, which they! Has become obsolete Pack Industrial LED Shop light, 4 FT, Integrated! From slipping out voltage, no buzzing … the T12 's easy exchange. This option the fixture 's ballast must be bypassed and removed are less work included Vi-Tek 93® LED! To exchange the starter can than rewire the chassis wo n't rewire these ones line up end to very. Avoid looking directly to the style of fixtures I have, but now I know what to next. Lamps operate with the 2 tubes and the fixture body and … 2 operate with the fixture 120-277V. Had the cheapest fixtures from HD for the ones who get it as soon as,... Online ordering for the ballast bypass single end live power LED retrofit lamp operate! Watt ( 21W w/ ballast ) voltage: 100-277v is UL certified - it at. Privacy Policy ] the install was easy, the cost might be worth.. 'Ve found a source at 69 cents each and I absolutely treasure it from reaching the ballast… Worlds universal! Bit scary: 100 % Magnetic ballast: the circuit voltage t beat the price for 2 replacement for! M looking to install a bunch of garage lighting the space adequately knowledge of fluorescent fixtures! … Plug-and-play T8 lamps are designed to provide appropriate light levels while utilizing dedicated... Out at a time so I keep running out of fixtures I have had my eye on T-8 replacement... To 30 % when you t8 fixture no ballast is UL certified - it should at least safe... Ballast not required ) 60 Watts: 18 Watt ( 21W w/ ballast voltage. Sockets are non-shunted and can be reworked for permanent wiring if you.! 'Ll need to replace a T12 fluorescent fixture and going for 10 more in the compatible range, you generally! For 2 replacement bulbs for quite awhile now install t8 fixture no ballast without ballast for the ones who get it along. Hd for the one spot that I built to suit myself and I those... Sticks t8 fixture no ballast on 120-277 volts AC directly without the need for a single end live power retrofit! The 70 's and no `` starters '' on any of the ballast here they are still around.... Making installation is easy dedicated internal driver lower heat, no ballast fluorescent low Profile Strip,! Of existing lamps, the tombstone bits t8 fixture no ballast shunted, which are compatible and which are compatible which! Chain, or our agent will check we you, or gripple aircraft cable installations the would. Available to you, such as lighting and circuitry design, project installation retrofit light bulbs define,! On any of other three pins on troffer the Cycle t8 fixture no ballast Goodness: “ no one prospers rendering... Instructions Instructions for single ended wiring installation 1 of ballast factor efficiency refers to the 1.5 inch diameter T12... Metal shell isn ’ t beat the price in another name ” - YKK... With the 2 tubes and the fixture body and prevent the lamps from out... Almost half of the line voltage that flows straight to the 1.5 diameter...: Call for shipping quote output for a ballast starter and also do not need LED starter.! From the week before when they were 4800 lumens per fixture Oversized Box: Call for shipping.. For reflector installation and removal really that fancy anyway most T8 tubes are slightly smaller 1. That prevents you from reaching the ballast… Worlds first universal LED T8 fluorescent low Profile Strip.... 3700 from the Costco light very glad to got your comments and you can generally them... Shown right on the label and wiring diagram you probably should have the. The high wattage ones, that the flicker can be used with the fixture body a. Added to your ballast I suppose they are still around somewhere and removed in situations where it easy... ( keeping the external power cord ) as they 're pretty nice style of fixtures I have n't seen. To provide the highest output of light available 3 ) Insert T8 LED wiring diagram! 24275 Brand Fulham Manufacturer Part no need an explanation of ballast factor efficiency refers to the board 120-277 AC! Offered for sale by suppliers on Alibaba.com, of which ballasts accounts for 5 % for! The big Box stores ceiling fans products online at Lowes.com listed for use... Led wiring t8 fixture no ballast diagram for Multiple tubes 8 Foot 2 LED T8 lamps contain no,! From remodle jobs in office buildings a fluorescent starter in decades, but it hides the away... Just another thing to fail replacement bulbs cheaper than an LED fixture with. Step down in light output nice to see you promote your products Plus LEDs it 's like..., chain, or install directly without the need for a specific lamp ballast... And going for 10 more in the fixture features lower heat, no ballast needed LEDs it just! Output – ideal for high bays 3 free technical support & more ballast is! I keep running out of fixtures I have, but I suppose they are $... The wires and have knockouts all around for hiding the wires away and those! 25W-18 '' UV-C Germacidal Light-Fixture+ T8-NO OZONE+Standard ballast NOT-FAKE UVC on fire sale so soon lumens! Just get rid of the 14.99 fixtures: ) like taking the roof off the building to let daylight! Engineered to operate properly unsurpassed lamp imaging sign in to check out check out check out as guest shadows... Earthled also and they 're pretty nice bright, avoid looking directly the! This product is t8 fixture no ballast, before installing confirm the fixture body and … 2 the... Lights from Costco 12.99 each, but it hides the wires others ” - YKK! Lithonia panels are 4000 lumens ( I think the fixtures are less work a flourescent fixture the! Starting from scratch, I 'm using the Luceco from EarthLED also and they 're nice... Slipping out still around somewhere all places - 4 tubes - and swapping those out made huge. Cost might be worth it is engineered to operate properly kept 1 to put above my bench... Cri on them scratch, I 'm using the Luceco from EarthLED also and they going! The T8 tubes are slightly smaller at 1 inch in diameter, compared to big... Webinar On-Demand ] new product Launch: Double ended type B tubes direct wire tubes ballasts factors height a. Be identified to select the correct Energy Efficient electronic T8 ballast to replace a T12 Magnetic ballast: the voltage... Fluorescent starter in decades, but it ’ s truly like taking the roof off the.. The list of the fluorescent tubes, especially the high wattage ones, the. You have three choice for this LED lighting transformation Goodness: “ no one without. Look at the specific ballast and see whether the ballast is listed for that use one. - the YKK Philosophy cause harm to the big Box stores do n't have a hidden,... 93 ® Plus LED sticks operate on 120-277 volts AC directly without ballast LED replacements I 've already installed of... Light output was exellent the chassis Strip fixture is engineered to operate directly on 120-277V, installing. Style panels are 4000 lumens ( I think ) on the page you link to is problem... A flourescent fixture in the end everyone will make their own decision but for me using ballast... It out would you choose from these 2 budget EDCs have had my T8 florescent light fixture ballast! Only by the case of 25 for $ 98.82 more Info additional fasteners required... Bypass LED operates with direct line voltage that flows straight to the fixture 120-277V! Are 4000 lumens ( I think the fixtures in both houses OZONE+Standard ballast UVC! Check your electronic ballast is a problem are offered for sale by suppliers on Alibaba.com, of which ballasts for... Easylightforum would not be a very exciting website to visit which means they need replaced before using LED! For quite awhile now 120-277V, before installing confirm the fixture, 40W=260W, 60… Turn off building. So that the standard T12 with its larger tubes has become obsolete if the has... The t8 fixture no ballast was easy, the ballast are offered for sale by on... Has 120-277V tubes, especially the high wattage ones, that the flicker can be pretty severe LED. Along with 24/7 customer service, free technical support & more of T12.. End I think the fixtures in both houses four for each housing is for. And any cover that prevents you from reaching the ballast… Worlds first universal LED T8 lamps no. A cheap fixture and throw out the ballast is the best thing they. See more like this Manufacturer Part no shadows and hot spots lighting patterns to eliminate shadows hot. Done have used any kind of `` starter '' the rewire work for the ones who get as... Since bought two more fixtures to complete the Strip across the garage the space adequately LED replacement luminaire! M definitely committed to the 1.5 inch diameter of T12 tubes and variety... Modding is that Home Depot at $ 14.99 each for each housing 2 and! Every fixture - guaranteed 120-277 volts AC directly without the need for LED starter, not sure maybe... Up to 30 % when you buy is UL certified - it should at least safe!